Infrastructure

Nikon A1R confocal Microscope

Type
Equipment
Acronym
Nikon A1R
Code
APP/00048
Date of commissioning
29 January 2010 → …
Research disciplines
  • Natural sciences
    • Nanophysics and nanosystems
    • Proteins
    • Epigenetics
    • Parasitology
    • Epigenetics
    • Phytopathology
    • Plant biochemistry
    • Plant cell and molecular biology
    • Plant immunology
    • Transcriptomics
  • Engineering and technology
    • Biomaterials
    • Polymer composites
    • Biomedical image processing
    • Molecular and cellular biomechanics
    • Medical biotechnology not elsewhere classified
    • Environmental plant biotechnology
  • Agricultural and food sciences
    • Agricultural plant protection
    • Crop science
    • Agricultural plant breeding and biotechnology
    • Food sciences and (bio)technology not elsewhere classified
Keywords
confocal Fluorescence linear unmixing Microscope Imaging spectral imaging live cell imaging controlled light exposure microscopy fast confocal imaging resonant scanner optical sectioning
Brand Name/manufacturer
Nikon
Other information
 
Description

Confocal laser scanning microscopy (CLSM) is a widely used technique in the life sciences for making high-quality images of biological samples. The samples are illuminated by a focused laser beam which is scanned over the sample in order to visualize fluorescent markers. Emission from each position is detected by a point detector and a pinhole removes out of focus emission light to improve contrast and resolution. CLSM results in optical sectioning and a 3D reconstruction of the sample can be made.

The Nikon A1R has the additional possibilities to scan very fast with its resonant scanner (30 FPS), to observe scattering particles and to perform spectral imaging and lineair unmixing.

Specifications:

  • Objectives:
    • 10X plan apo AIR dic N1(NA 0,45; WD 4; brightness 4,10) MRD70170
    • 20X plan fluor AIR dic N2 (NA 0,5; WD 2,1; brightness 1,56) MRH00205
    • 40X S plan fluor ELWD AIR (NA 0,6; WD 3,6-2,8; brightness 0,81) MRH08430
    • 40X plan fluor OIL dic H/N2 (NA 1,3; WD 0.2; brightness 17,85) MRH01401
    • 60X plan apo VC OIL dic N2 (NA 1,4; WD 0.130; brightness 10,67)
    • 60X plan apo VC H2O dic N2 (NA 1,2; WD 0,31-0,28; brightness 5,76) MRD07602
  • Lasers:
    • 4 lasers with in total 7 laser lines: 405 nm, 457 nm, 476 nm, 488 nm, 514 nm, 561 nm, 639 nm
    • 2 separated lasers for Controlled Light Exposure Microscopy (488 & 543 nm)
  • Scanners:
    • Galvoscanner
    • Resonantscanner.
  • Simultaneous use possible for photo-stimulation experiments (FRAP, FRET, ...)
  • Detectors:
    • Simultaneous 2-channel GAaSP en 2-channel PMT detection
      • Channel 1: 450/50 or 482/35
      • Channel 2: 525/50 or 540/30 or 515/30
      • Channel 3: 595/50 or 585/65
      • Channel 4: 700/75
    • 32-channel PMT spectral detector with resolution of 2.5, 6 or 10 nm per channel
  • Piezo stage for fast and precise scanning in the z direction
  • Perfect Focus System
  • Incubator with temperature regulation at the microscope level and CO2 at the cell culture level